Managed OpenStack
Latest
Introspection Fails During Baremetal Provisioning Due to the FMS Error
Problem
During baremetal provisioning, Introspection fails due to the FMS Error.
Environment
Platform9 Managed OpenStack - v8.0 and Higher
Ironic Regions
Cause
This is a known bug and is reported internally with ID: IAAS-10796
In ironic-inspector logs (on Management Plane), check for the below logs.
The dnsmasq filter sync fails while fetching
ironic_macsin dnsmasq driver due to 504 error.
[Timestamp] 25367 ERROR ironic_inspector.pxe_filter.base [-] The PXE filter DnsmasqFilter, state=initialized encountered an exception: HttpException: 504: Server Error for url: https://[DU-FQDN]/ironic/v1/ports?fields=address, 504 Gateway Time-out: nginx/1.18.0; resetting the filter: openstack.exceptions.HttpException: HttpException: 504: Server Error for url: https://[DU-FQDN]/ironic/v1/ports?fields=address, 504 Gateway Time-out: nginx/1.18.0
[Timestamp] 25367 DEBUG ironic_inspector.pxe_filter.base [-] Resetting the PXE filter driver DnsmasqFilter, state=initialized reset /opt/pf9/ironic-inspector/lib/python3.9/site-packages/ironic_inspector/pxe_filter/base.py:121
[Timestamp] 772 25367 WARNING ironic_inspector.pxe_filter.base [-] Filter driver DnsmasqFilter, state=uninitialized disabling periodic sync task because of an invalid state.: ironic_inspector.pxe_filter.base.InvalidFilterDriverState: The PXE filter driver DnsmasqFilter, state=uninitialized: my fsm encountered an exception: Can not transition from state 'uninitialized' on event 'sync' (no defined transition)
The following introspection attempt after this fails due to the FSM error.
[Timestamp] 25367 INFO ironic_inspector.node_cache [-] Node [Node UUID] was created successfully
[TImestamp] 417 25367 ERROR ironic_inspector.node_cache [-] [node: [Node UUID] state processing] Processing the error event because of an exception <class 'ironic_inspector.pxe_filter.base.InvalidFilterDriverState'>: The PXE filter driver DnsmasqFilter, state=uninitialized: my fsm encountered an exception: Can not transition from state 'uninitialized' on event 'sync' (no defined transition) raised by ironic_inspector.process._process_node: ironic_inspector.pxe_filter.base.InvalidFilterDriverState: The PXE filter driver DnsmasqFilter, state=uninitialized: my fsm encountered an exception: Can not transition from state 'uninitialized' on event 'sync' (no defined transition)
Workaround
Workaround is to add exception handling for the ironic API call.
Patch the controller host with below fix:
$ sudo vim /opt/pf9/ironic-inspector/lib/python3.9/site-packages/ironic_inspector/pxe_filter/dnsmasq.py +88
---
try:
# active_macs are the MACs for which introspection is active
active_macs = node_cache.active_macs()
# ironic_macs are all the MACs know to ironic (all ironic ports)
ironic_macs = set(port.address for port in
ir_utils.call_with_retries(ironic.ports, limit=None,
fields=['address']))
except Exception:
LOG.exception(
"Could not list ironic ports, can not sync dnsmasq PXE filter")
return
Restart Ironic services
$ sudo systemctl restart pf9-ironic-*
Additional Information
The issue is fixed in the Platform9 Managed Openstack v5.10.1 Release.
Last updated on
Was this page helpful?
Frequently Asked Questions
Solution
How To
Internal Only
Templates
Powered by